Special Purpose Units – Compressors for Soil Sparging

Special Purpose Units – Compressors for Soil Sparging
Oilless operation, Rugged construction/low maintenance, Heavy-duty filters

Separate Drive Rotary Vane
Oilless 0823, 2080/3080, 2067/2567, 6066, and 1290 Series

Model 0823

10 psi max. continuous pressure
8 CFM open flow

Models 2080/3080

15 psi max. pressure
25-35 CFM open flow

Models 2067/2567

20 psi max. pressure
17-21 CFM open flow

Models 2066

20 psi max. pressure
37-55 CFM open flow

Models 1290

20 psi max. pressure
112 CFM open flow

Product Features
  • Oilless operation
  • Rugged construction/low maintenance
  • Heavy-duty filters
Recommended Accessories
  • Pressure gauge AA644B
  • Relief valves:
    AA600 (0823)
    AN225 (2080, 3080)
    AA307 (2067, 2567, 6066, 1290)
  • Repair kits:
    K479A (0823)
    K546 (2080, 3080)
    K585 (filter/muffler kit for 2080)
    K584 (filter/muffler kit for 3080)
    K357 (2067, 2567)
    K503 (6066, 1290 – use 2)

Product Dimensions (inches, mm)

Dimensions are for reference only

Top View

Side View

Product Specifications

Note: Note: All models are compressors.

Model Number Motor RPM HP kW Net Weight
60 cycle 50 cycle lbs kg
0823-P155-SG608X*  100-110/220-240-50-1
110-115/208-230-60-1
1725 1425 ³/₄ 0,56 50 22,5
2080-P124-T337† 230/460-60-3 1725  - 2 1,5 135 60,8
3080-P124-T338† 208-230/460-60-3 1725  - 3 2,2 160 72,0
2067-P118-G470X† 115/230-60-1 1725  - 1 ¹/₂ 1,1 84 37,8
2067-P118-G471*† 220/380-415-50-3
208-230/460-60-3
1725 1425 1
1 ¹/₂
0,75
1,1
84 37,8
2567-P132-T908X† 115/230-60-1 1725  - 2 1,5 85 38,3
6066-P122A For 213T or 215T frame motor 1725  - 7 ¹/₂ 5,6 88 39,6
6066-P122-T339***† 208-230/460-60-3 1725  - 5 3,7 205 92,3
1290-P110 For 215T frame motor 1725  - 10 7,5 220 99,7
1290-P110A For 254T frame motor 1725  - 15 11,1 230 104,0

*For 50 Hz performance, reduce air flow on grid by approximately 17%/
***These models are capable of 15 psi max. performance, reference performance grid below.
Consult factory or distributor for the correct Nema frame size motor to use. Customer supplied motor must have minimum service factor of 1.15.

Product Performance